Active Network Systems Ltd

Subsystems

Subsystems incorporate hardware RAID controllers with hot swappable disk drives, allowing RAID functionality to be added to systems, offering hot swap drives, redundancy and resilience. Transparent to the host operating system and requiring no drivers, they do not consume CPU cycles or memory bandwidth. Typical applications include small servers, industrial computing hardware and DVR / DAR for CCTV.

SATA

SATA 2x2.5"

Accusys 7521x Series


ACS-75210

ACS-75210

  • Occupies 1 x 3.5" drive bay (5.25" option)
  • PATA host, SATA 2.5" drives
  • Hardware RAID 1
  • Individual disks may be used on separate controller
  • May be used to duplicate disks
  • Web GUI allows remote status monitoring and notification
Dimensions Humidity
3.5": 150 x 100 x 25.4mm (LxWxH) Operating: 5% to 85% non-condensing
5.25": 150 x 148 x 40mm (LxWxH) Non-operating: 5% to 95% non-condensing
Power Requirement MTBF
+5.0V DC/0.5A ±5% >100,000 POH
Temperature Certification Compliance
Operating 0C to 40C FCC, CE, UL, RoHS
Non-operating: -25C to 60C  

75210_datasheet_web.pdf

ACS-75210 on Accusys' Website


To top

ACS-75211

ACS-75211

  • Occupies 1 x 3.5" drive bay (5.25" option)
  • SATA host, SATA 2.5" drives
  • Hardware RAID 1
  • Individual disks may be used on separate controller
  • May be used to duplicate disks
  • Web GUI allows remote status monitoring and notification
Dimensions Humidity
3.5": 150 x 100 x 25.4mm (LxWxH) Operating: 5% to 85% non-condensing
5.25": 150 x 148 x 40mm (LxWxH) Non-operating: 5% to 95% non-condensing
Power Requirement MTBF
+5.0V DC/0.5A ±5% >100,000 POH
Temperature Certification Compliance
Operating 0C to 40C FCC, CE, UL, RoHS
Non-operating: -25C to 60C  
Download ACS-75211 Datasheet ACS-75211 on Accusys' Website

75210_datasheet_web.pdf

ACS-75211 on Accusys' Website


To top

SATA 2x3.5"

Accusys 75xx Series


ACS-75170

  • SATA host, 2 x SATA drives
  • Hardware RAID 1
  • Individual disks may be used on separate controller
  • May be used to duplicate disks
  • Web GUI allows remote status monitoring and notification
  • Available in black (ACS-75170B) or white (ACS-75170W)
Dimensions Humidity
224 x 146 x 85mm (LxWxH) Operating: 5% to 85% non-condensing
Power Requirement Non-operating: 5% to 95% non-condensing
+5.0V DC ±5%, +12.0V DC ±10% MTBF
Temperature >300,000 POH
Operating 5C to 40C Certification Compliance
Non-operating: -25C to 60C FCC Class B, CE, C-Tick, UL Approval

7500_7510_75170_datasheet_web.pdf

ACS-75170 on Accusys' Website


To top

ACS-75200

  • SATA host, SATA drives
  • RAID 0, 1
  • Individual disks may be used on separate controller
  • May be used to duplicate disks
  • Web GUI allows remote status monitoring and notification
  • Available in black (ACS-75200B) or white (ACS-75200W)
Dimensions Humidity
224 x 146 x 85mm (LxWxH) Operating: 5% to 85% non-condensing
Power Requirement Non-operating: 5% to 95% non-condensing
+5.0V DC ±5%, +12.0V DC ±10% MTBF
Temperature >100,000 POH
Operating 0C to 40C Certification Compliance
Non-operating: -25Cto 60C FCC, CE, UL, RoHS

75200_76200_datasheet_web.pdf

ACS-75200 on Accusys' Website


To top

SATA 3x3.5"

Accusys ACS-76xxx Series


ACS-76130

ACS-76130

  • SATA host, 3 x SATA drives
  • Hardware RAID 0, 5, user selectable
  • Web GUI allows remote status monitoring and notification
  • Available in black (ACS-76130B) or white (ACS-76130W)
Dimensions Humidity
224 x 146 x 85mm (LxWxH) Operating: 5% to 85% non-condensing
Power Requirement Non-operating: 5% to 95% non-condensing
+5.0V DC ±5%, +12.0V DC ±8% MTBF
Temperature >300,000 POH
Operating 5C to 40C Certification Compliance
Non-operating: -25C to 60C FCC Class B, CE, UL Approval, RoHS

7630_76130_datasheet_web.pdf

ACS-76130 on Accusys' Website


ACS-76510

ACS-76510

  • SATA host, 3 x SATA drives
  • Hardware RAID 1 + backup to 3rd disk
  • Split mirroring with snapshot
  • Manual or automated backup via GUI
  • Individual disks may be used on separate controller
  • May be used to duplicate disks
  • Web GUI allows remote status monitoring and notification
  • Available in black (ACS-76510B) or white (ACS-76510W)
Dimensions Humidity
224 x 146 x 85mm (LxWxH) Operating: 5% to 85% non-condensing
Power Requirement Non-operating: 5% to 95% non-condensing
+5.0V DC ±5%, +12.0V DC ±8% MTBF
Temperature >300,000 POH
Operating 5C to 40C Certification Compliance
Non-operating: -25C to 60C FCC Class B, CE, UL Approval, RoHS

76500_76510_datasheet_web.pdf

ACS-76510 on Accusys' Website


ACS-76500

ACS-76500

  • PATA host, 3 x PATA drives
  • Hardware RAID 1 + backup to 3rd disk
  • Split mirroring with snapshot
  • Manual or automated backup via GUI
  • Individual disks may be used on separate controller
  • May be used to duplicate disks
  • User selectable Master / Slave
  • Web GUI allows remote status monitoring and notification
  • Available in black (ACS-76500B) or white (ACS-76500W)
Dimensions Humidity
224 x 146 x 85mm (LxWxH) Operating: 5% to 85% non-condensing
Power Requirement Non-operating: 5% to 95% non-condensing
+5.0V DC ±5%, +12.0V DC ±8% MTBF
Temperature >300,000 POH
Operating 5C to 40C Certification Compliance
Non-operating: -25C to 60C FCC Class B, CE, UL Approval, RoHS

76500_76510_datasheet_web.pdf

ACS-76500 on Accusys' Website


ACS-76200

ACS-76200

  • SATA host, 3 x SATA drives
  • Hardware RAID 0, 1s, 1+Backup, 5 (user selectable)
  • RAID level migration by GUI
  • Web GUI allows remote status monitoring and notification
  • Available in black (ACS-76200B) or white (ACS-76200W)
Dimensions Humidity
203 x 146 x 85mm (LxWxH) Operating: 0% to 85% non-condensing
Power Requirement Non-operating: 0% to 95% non-condensing
+5.0V DC ±5%, +12.0V DC ±10% MTBF
Temperature >100,000 POH
Operating 0C to 40C Certification Compliance
Non-operating: -25Cto 60C FCC, CE, UL, RoHS

75200_76200_datasheet_web.pdf

ACS-76200 on Accusys' Website


SCSI

SCSI 2x3.5"

Acard ARS-2018 MirrorSmart Series


ARS-2018i

ARS-2018i

Internal Ultra160 SCSI-to-SATA RAID 1 subsystem with hot-swap SATA hard disk drives.

  • Supports hardware RAID 1, JBOD and NRAID
  • Provides easy LCD operation mode to display status and set up system
  • Supports instant Rebuilding (up to 3.0 GB/min)
  • Automatic fan speed control
  • Audible, visible and e-mail alarm notification
  • May be daisy-chained on SCSI bus
  • SCSI ID select 0-15
Dimensions Humidity
215 x 148 x 85mm (LxWxH) Operating: 10% to 75% non-condensing
Power Requirement Temperature
+5.0V DC ±5%, +12.0V DC ±10% Operating: 5C to 40C
ARS-2018i on Acard's Website Non-operating: -25C to 60C

To top

ARS-2018E

ARS-2018E

External Ultra160 SCSI-to-SATA RAID 1 subsystem with hot-swap SATA hard disk drives.

  • Supports hardware RAID 1, JBOD and NRAID
  • Provides easy LCD operation mode to display status and set up system
  • Supports instant Rebuilding (up to 3.0 GB/min)
  • Automatic fan speed adjustment
  • Audible, visible and email alarm notification
  • May be daisy-chained on SCSI bus
  • SCSI ID select 0-15

To top

Dimensions Humidity
280 x 172 x 152mm (LxWxH) Operating: 10% to 75% non-condensing
Power Requirement Temperature
+5.0V DC ±5%, +12.0V DC ±10% Operating: 5C to 40C
ARS-2018E on Acard's Website Non-operating: -25C to 60C

To top

ARS-2019

ARS-2019

External USB2.0-to-SATA RAID 1 subsystem with hot-swap SATA hard disk drives.

  • Supports hardware RAID 1, JBOD and NRAID
  • Provides easy LCD operation mode to display status and set up system
  • Supports instant Rebuilding (up to 480Mb/s)
  • Automatic fan speed adjustment
  • Audible, visible and e-mail alarm notification
Dimensions Humidity
280 x 172 x 152mm (LxWxH) Operating: 10% to 75% non-condensing
Power Requirement Temperature
+5.0V DC ±5%, +12.0V DC ±10% Operating: 5C to 40C
ARS-2019 on Acard's Website Non-operating: -25C to 60C

To top

SCSI 4x3.5"

Acard ARS-3000 RAIDbox Series

Acard's ARS-3000 RAIDbox Series is a range of 1U 4-bay storage devices suitable for DVR / DAR / Media Streaming system storage, or any other devices with a SCSI host bus. The Ultra SCSI LVD host interface sees the four internal disks with a single SCSI address, which enables up to 15 RAIDbox devices to be daisy-chained on a single SCSI bus. With currently available disk sizes this offers a maximum capacity of some 90TB.

ARS-3010S

ARS-3010S

The ARS-3010S is a SCSI-to-SATA external data storage device which offers either JBOD or NRAID disks.

  • JBOD and NRAID disks
  • Ultra 160 LVD SCSI host interface
  • SCSI ID selectable between 0 and 15
  • SATA-150 disk interface
  • 1U rackmount 44hx483wx400d (mm)
  • Onboard LEDs for disk status and warning
ARS-3030

ARS-3030

The ARS-3030 is a SCSI-to-SATA external data storage device which offers either JBOD, spanned disks or RAID functionality.

  • RAID0, 0+1, 3, 5, JBOD, NRAID
  • Supports hot spare
  • LCD monitor for operation display and configuration setting
  • Hot swap disks
  • Ultra 160 LVD SCSI host interface
  • SCSI ID selectable between 0 and 15
  • SATA-150 disk interface
  • 1U rackmount 44hx483wx460d (mm)
  • Onboard LEDs for disk status and warning
ARS-3030N

ARS-3030N

The ARS-3030N is a SCSI-to-SATA external data storage device which offers either RAID, JBOD or NRAID functionality, and may be monitored over Ethernet.

  • RAID0, 0+1, 3, 5, JBOD, NRAID
  • Supports hot spare
  • LCD monitor for operation display and configuration setting
  • E-mail notice of disk failure
  • Hot swap disks
  • Ultra 160 LVD SCSI
  • SCSI ID selectable between 0 and 15
  • SATA-150 disk interface
  • 1U rackmount 44hx483wx460d (mm)
  • Onboard LEDs for disk status and warning
ARS-3031

ARS-3031

The ARS-3030N is a SCSI-to-SATA external data storage device which offers either RAID. JBOD or NRAID functionality, and may be monitored over Ethernet.

  • RAID0, 0+1, 3, 5, JBOD, NRAID
  • Supports hot spare
  • Externally accessible hot swap disks
  • E-mail notice of disk failure
  • Ultra 160 LVD SCSI host interface
  • SCSI ID selectable between 0 and 15
  • SATA-150 disk interface
  • 1U rackmount 44hx483wx460d (mm)
  • Onboard LEDs for disk status and warning

To top


PCIe

PCIe 4x3.5"

Accusys ACS-61020 Series

Powerful yet affordable, external storage arrays with PCIe RAID controller for PC and Mac users, with a Java based GUI for remote management. These systems support Windows (they are 2000, 2003, 2008, XP, Vista 32/64 certified), Mac OS and Linux.

Tom's Hardware test of Accusys iRAIDer ACS-61020

Tom's Hardware test of ACS-61020CB controller


ACS-61020-4

External enclosure with 4 x hot swap SATA drive bays.

  • 1 x 4-bay chassis
  • 1 x 4-port ACS-61020-4 RAID card
  • 1 x external 2-metre SAS cable
  • 1 x SES management cable
  • RAID 0, 1, 5, 0+1 and JBOD

61020_web.pdf

ACS-61020-4 on Accusys' Website


To top

PCIe 8x3.5"

Accusys ACS-61020 Series

Powerful yet affordable, external storage arrays with PCIe RAID controller for PC and Mac users, with a Java based GUI for remote management. These systems support Windows (they are 2000, 2003, 2008, XP, Vista 32/64 certified), Mac OS and Linux.

Tom's Hardware test of Accusys iRAIDer ACS-61020

Tom's Hardware test of ACS-61020CB controller


ACS-61020-8

External enclosure with 8 x hot swap SATA drive bays.

  • 1 x 8-bay chassis
  • 1 x 8-port ACS-61020-4 RAID card
  • 2 x external 2-metre SAS cables
  • 1 x SES management cable
  • RAID 0, 1, 5, 6, 0+1 and JBOD

61020_web.pdf


To top

ACS-61020-8 on Accusys' Website


To top