Active Network Systems Ltd


Qsan RAID Systems



P500Q-D316 / P500Q-S316 / P600Q-C316

10 GbE iSCSI-SAS 3U 16-bay High Availability RAID Storage

P500Q-DSC316.pdf

Features

  • Two 10GbE + two 1GbE iSCSI ports per controller
  • Up to 780K IOPs & 4000MB/Sec. throughput
  • Fully redundant & hot pluggable designs: RAID controllers, power supplies, fan modules, battery backup modules, & JBOD expansion
  • Hardware iSCSI offloaded engine
  • Green storage designs: auto disk spin down, advanced cooling mechanism, & 80 PLUS energy-efficient power supplies
  • Advanced data protection: RAID 6, 60, QSnap writeable snapshot, QReplica remote replication, Windows VSS support, volume cloning
  • Flexible volume management for multiple applications & environments: virtualization (VMWare, Hyper-V, Citrix), cloud storage, SQL, Exchange, surveillance, file backup, email, boot from SAN, & etc.
  • High connection availability: load balancing & failover
  • Extendable capacity up to 192 hard drives

Performance

- Maximum IOPS: 70,000

- Maximum throughput: 3000MB/s

- Performance is substantially higher than other curently available comparable storage systems

Applications

- Optimized IOPS and throughput are capable of providing run-time critical online services such as Cloud storage, SQL, Exchange, and high-end CCTV storage.

- 10GbE iSCSI interface is ideal for virtualization environments such as VMWare, Hyper-V, and Citrix.

- Users may install up to 32 OSs in the 10GbE iSCSI system through the Boot-from-SAN feature. 

- Multiple OSs / Servers readily managed and well protected by Qsan’s advanced data protection features - no system downtime caused by single point of failure.

High Availability

- J300Q systems are well equipped with fully redundant components for all major functions, including redundant RAID controllers, power supplies, fan modules, battery backup modules, and SAS JBOD expansion ports.

- Firmware includes support for RAID 6, 60, QSnap writable snapshot, Windows VSS support and volume configuration restoration reduces the chances of rebooting or shutdown, and may be upgraded without system down time.

- Firmware image and volume handling are protected by redundant RAID controllers; when one RAID controller is down or has lost the connection, the other RAID controller takes over its tasks immediately with the volumes and the services are transferred seamlessly and simultaneously.

Environmental

- Auto disk spin down minimises hard drive power consumption, and is unnoticeable to users.

- Active temperature monitoring and interactive cooling fan control.

- Power supply modules are all 80 PLUS power efficient for better power conversion.




To top